Skip to content
CUFAGROUP

Technology

How the air changes without losing the heat.

HumidityCO₂Condensation

The problem

Closed windows keep everything in.

Modern buildings and new windows are airtight. Moisture, CO₂ and pollutants stay in the room. Opening the windows in winter throws the heat out and lets in noise and dust.

The copper

Air goes out and comes in at once, never mixing.

Stale room air flows through the copper exchanger's channels and leaves its heat in the copper. In the neighbouring channels, fresh outdoor air picks that heat up. Copper's natural antiseptic properties stop bacteria and microbes spreading from the unit.

+20 °C+19 °C+1 °C0 °CInsideOutsideup to 98% efficiency

The result

At 0 °C outside, air comes in at about +19 °C.

Room air at +20 °C leaves at about +1 °C, because it has left its heat in the copper. Outdoor air at 0 °C comes in warmed to about +19 °C. That's up to 98% efficiency.

Four functions

So it runs all year, winter included.

  • Mini-heating

    Protects the heat exchanger from freezing in the cold season and raises the incoming air by 3–4 °C in night mode.

    InStandardPremiumPremium Plus

  • Winter mode

    Defrosts and warms the system after a stop and before the cold season, so frozen moisture can't damage the fans. Use it together with Mini-heating when it's below +4 °C outside.

    InStandardPremiumPremium Plus

  • AUTO

    The ventilation adjusts itself to humidity, CO₂ and air quality (VOC), depending on the configuration. Mini-heating and Winter mode switch on and off by themselves.

    InPremiumPremium Plus

  • AUTO PLUS

    Works like AUTO, with the power capped so it stays quieter. Recommended for bedrooms and rest areas.

    InPremiumPremium Plus

The sensors

What each one measures, and which configurations have it.

  • CO2 eq sensor

    How stale the air is from breathing. In AUTO, the ventilation steps up as it rises.

    Premium Plus

  • Air quality sensor, VOC

    Fumes from cleaning, cooking, furniture and paint.

    Premium Plus

  • Air humidity sensor

    Air humidity, the cause of condensation and mould.

    PremiumPremium Plus

  • Temperature sensor 1

    Outgoing air temperature before recovery.

    PremiumPremium Plus

  • Temperature sensor 2

    Incoming air temperature after recovery.

    PremiumPremium Plus

  • Temperature sensor 3

    Incoming air temperature during recovery.

    StandardPremium Plus

  • Atmospheric pressure sensor

    Atmospheric pressure.

    PremiumPremium Plus

Window, PRANA or a central system?

Three ways to change the air.

Open windowPRANACentral ducted system
The heat stays insideup to 98%
Noise and dust stay outside
No ducts or suspended ceilings
For an existing home≈ 2 h per unitusually during construction
The maker

The maker

PRANA invents and makes patented energy-saving technologies. For 18 years it has offered energy-efficient ventilation around the world. Today it is releasing the fifth generation of its recuperators with a copper heat exchanger, tested in the manufacturer's own climate laboratory. PRANA is based in Lviv, Ukraine.

18
years of experience
5
generations of recuperators
A+
energy class, by configuration
CE
meets EU standards
CGWe're available

Breathe easy.

We'll propose the model and number of units, free of charge.